Enforce Dell BIOS Settings

Purpose​

This solution keeps BIOS settings on Dell workstations in line with a standard you define, for example powering on every day at 9 PM and allowing the device to wake from the network or when power is connected. Start in Audit mode to see which devices differ, then switch to Enforce to apply the settings. Applied settings take effect after the next restart.

Associated Content​

Custom Fields​

NameExampleTypeLevelRequiredPurpose
cPVAL Enforce Dell BIOS SettingsAuditDrop-downOrganization, Location, DeviceYesTurns the solution on in Audit or Enforce mode.
cPVAL Dell BIOS SettingsAutoOnHr=21Multi-lineOrganization, Location, DeviceYesThe expected BIOS settings, one per line.
cPVAL Dell BIOS Settings StatusCompliantTextDeviceYesShows the result on each device. Read-only.

Automation Scripts​

NamePurpose
Check Dell BIOS SettingsChecks the BIOS settings and stores the result. Triggers the apply script in Enforce mode.
Apply Dell BIOS SettingsApplies the settings that differ and flags the device for a restart.

Compound Condition​

NamePurpose
Enforce Dell BIOS SettingsRuns the check once a day on Dell workstations where the solution is set to Audit or Enforce, and runs the apply script when needed.

Implementation​

Step 1: Create the custom fields​

Step 2: Import the automations​

Step 3: Create the compound condition​

Create Compound Condition: Enforce Dell BIOS Settings in the Windows Workstation [Default] policy.

Step 4: Enter the expected settings​

Set cPVAL Dell BIOS Settings at the organization level. For example, to power on every day at 9 PM and allow Wake on LAN, Wake on AC and Wake on Dock:

AutoOn=Everyday
AutoOnHr=21
AutoOnMn=0
WakeOnAc=Enabled
WakeOnDock=Enabled
WakeOnLan=LanOnly
DeepSleepCtrl=Disabled

DeepSleepCtrl=Disabled lets models with Deep Sleep Control wake from a powered-off state. Models without a setting skip it. See cPVAL Dell BIOS Settings for the format rules.

Step 5: Audit the devices​

Set cPVAL Enforce Dell BIOS Settings to Audit at the organization level. After the next check, cPVAL Dell BIOS Settings Status shows Compliant or Non-Compliant on each Dell workstation, with the settings that differ.

Step 6: Enforce the settings​

Set cPVAL Enforce Dell BIOS Settings to Enforce. Settings that differ are applied, and the status shows Applied - Reboot Pending. Restart the devices to complete the change. After the restart, the status changes to Compliant.

FAQ​

Q: Do the devices restart automatically?
A: No. The solution sets the status to Applied - Reboot Pending. Restart the devices at a convenient time. The settings are verified after the restart.

Q: How do I exclude a location or device?
A: Set cPVAL Enforce Dell BIOS Settings to None at that location or device.

Q: What happens on models that do not support a setting?
A: The setting is skipped, and the rest are applied. Skipped settings are listed after Not supported in the status.

Q: Where do I find the option names and values?
A: See the Dell Command | Configure BIOS options reference. To see a setting's current value on a device, run the Dell Command | Configure automation with the option name, for example --WakeOnLan.

Q: What if a device has a BIOS setup password?
A: The change fails, and the status shows Failed with the reason. Devices with a BIOS password are not supported by this solution.

Q: Why does the check activity fail in Enforce mode?
A: A failed check means settings differ. It tells the compound condition to run the apply script.

Q: How do I see which devices are compliant?
A: Create a device group filtered on cPVAL Dell BIOS Settings Status, for example status contains Compliant, Reboot Pending or Failed.

Note: Changing BIOS settings affects how devices power on. Let users know that devices may turn on by themselves at the scheduled time.

Changelog​

2026-10-16​

  • Initial version of the document